.“.AJ----” -4-.;.-;. L J.-’- . .
.... . .... . .,
..0.
I
I
I
I
I
I
!
I
o
-.
[INCH-POUNDI
J-W-1177/32
June 10, 1988
FEDERAL SPECIFICATION SHEET
UIRE$ MAGNET, ELECTRICAL, CLASS 180, TYPE DgO
POLYESTER-GLASS-FIBER-COVERED,ORGANIC VARNISH TREATED, ROUND
This specification is approved by the Co-issioner, Federal Supply Service,
General Services Ministration, for the use of all Federal agencies~
The requirements for acquiring the wire described herein shall consist of this
specification and the latest issue of J-W-1177.
Classification:
(2t3S6 180;
type DgO and type Dg20 (bare with single or double
;
polyester-glass fiber, varnished),
type LDgO and type LX20 (single film, single Or
double polyester-glass fiber, varnished),
type L2Dg0 and type L2Dg20 (heavy film, single
or
double polyester-glass fiber, varnished); round.
Insulating materials:
The fiber%overing and application
of the covering
6hall be as specified in J_l?-1177.
If m under-
lying film coating Is used, it shall have a class
155 rating.
The varnish used in treating fibrous
covered wire shall conform to the requirements
of
class 180 of MIL-I-24092, or an alternate selected
on the basis
of equivalent test data.
The varnish
shall be a high temperature non-silicone insulating
varnish. The varnish used shall be identified in
the qualification test report.
NEMA/ANSI equivalent:
All test requirements are equivalent to MU-51 of ‘
NENA Mu 1000.
General requirements: See J-W-1177 for general requirements, quality
assurance provisions, and packaging.
AMC NiA
?Sc 0145
DISTRIBU’TIONSTATEMENT A Approved
for public release; distribution unlimited
Downloaded from http://www.everyspec.com