MIL DTL 3432G 详细规范 电缆(电力和特殊用途)和电线(300和600伏)(2000年10月27日)[取代MIL C 3432F]

ID:51679

大小:0.09 MB

页数:56页

时间:2023-03-23

金币:20

上传者:战必胜
Beneficial comments (recommendations, additions, deletions) and any pertinent data that may be of use
in improving this document should be addressed to: Defense Logistics Agency, Defense Supply Center,
Columbus (ATTN: DSCC-VAI), P.O. Box 3990, Columbus, OH 43216-5000, by using the Standardization
Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.
AMSC N/A FSC 6145
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
INCH-POUND
MIL-DTL-3432G
27 October 2000
SUPERSEDING
MIL-C-3432F
2 November 1992
DETAIL SPECIFICATION
CABLES, (POWER AND SPECIAL PURPOSE) AND WIRE, ELECTRICAL
(300 AND 600 VOLTS)
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers single and multiple conductor cables with and without shields
for use in 300 and 600 volts root mean square (rms) applications (see 6.1).
1.2 Classification. Cables covered in this specification are furnished in accordance with the type
designation specified and are classified by the element thereof.
1.2.1 Type Designation. The type designation is formed as follows:
M 3432 - 08 HG E (2/16S-4/12) SJ 1090
Part Number
(1.2.1.1)
Total number
of conductors
(1.2.1.2)
Class
(1.2.1.3)
Flexibility
(1.2.1.4)
Conductor
data
(1.2.1.5)
Shielding
under jacket
(1.2.1.6)
Outside
diameter
(1.2.1.7)
1.2.1.1 Part Number. Cables covered by this specification are identified by "M 3432" followed by a
hyphen.
1.2.1.2 Total number of conductors. The total number of conductors (see 6.3.1) in a cable,
exclusive of ground wires (see 6.3.2 and 6.3.4), is identified by a two-digit number. For cables with less
than 10 conductors, a "0" precedes the number of conductors (example - 04 = 4 conductors) in a multiple
conductor power cable.
1.2.1.3 Class. The class of cables is identified by a two-letter symbol, the first letter of which
designates the duty (see 6.1) in accordance with table I. The second letter indicates the application of the
cables in accordance with table II.
Downloaded from http://www.everyspec.com
资源描述:

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
关闭