INCH-POUND
MIL-DTL-3702D
09 January 2008
SUPERSEDING
MIL-DTL-3702C
8 September 2000
DETAIL SPECIFICATION
CABLE, POWER, ELECTRICAL: IGNITION,
HIGH-TENSION
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
1. SCOPE
1.1
Scope. This specification covers shielded and unshielded electrical power cable for use on high-
tension ignition systems (see
6.1).
1.2 Classification. Cable is classified as to type of shielding, cable diameter, temperature limit,
conductor material, and cable application.
1.2.1
Type designation. The type designation should include specification number-based cable
configuration identifying system (see
1.3 and 6.2). Example of type designation:
M
AMSC N/A FSC 6145
3702 U 5 L S A
Cable application (see 1.2.1.6).
Conductor material (see 1.2.1.5).
Temperature limit (see 1.2.1.4).
Cable diameter (see 1.2.1.3).
Type of shielding (see
1.2.1.2 ).
Specification number (see
1.2.1.1).
Prefix M (see 1.2.1.1).
1.2.1.1 Specification number. The type designation will consist of the defense specification number
with the prefix M.
1.2.1.2
Type of shielding. The type of shielding is identified by the letter U or S as follows:
U - Unshielded
S – Shielded
Comments, suggestions, or questions on this document should be addressed to Defense Supply Center-
Columbus, ATTN: DSCC-VAI, P.O. Box 3990, Columbus, OH 43218-3990, or emailed to
WireCable@dscc.dla.mil. Since contact information can change, please verify the currency of this
address information using the ASSIST Online database at http://assist.daps.dla.mil.
Downloaded from http://www.everyspec.com