MIL DTL 3702D 详细规范 电缆电源电气点火高张力(2008年1月8日)[取代MIL C 3702B]

ID:51707

大小:0.33 MB

页数:62页

时间:2023-03-23

金币:20

上传者:战必胜
INCH-POUND
MIL-DTL-3702D
09 January 2008
SUPERSEDING
MIL-DTL-3702C
8 September 2000
DETAIL SPECIFICATION
CABLE, POWER, ELECTRICAL: IGNITION,
HIGH-TENSION
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
1. SCOPE
1.1
Scope. This specification covers shielded and unshielded electrical power cable for use on high-
tension ignition systems (see
6.1).
1.2 Classification. Cable is classified as to type of shielding, cable diameter, temperature limit,
conductor material, and cable application.
1.2.1
Type designation. The type designation should include specification number-based cable
configuration identifying system (see
1.3 and 6.2). Example of type designation:
M
AMSC N/A FSC 6145
3702 U 5 L S A
Cable application (see 1.2.1.6).
Conductor material (see 1.2.1.5).
Temperature limit (see 1.2.1.4).
Cable diameter (see 1.2.1.3).
Type of shielding (see
1.2.1.2 ).
Specification number (see
1.2.1.1).
Prefix M (see 1.2.1.1).
1.2.1.1 Specification number. The type designation will consist of the defense specification number
with the prefix M.
1.2.1.2
Type of shielding. The type of shielding is identified by the letter U or S as follows:
U - Unshielded
S – Shielded
Comments, suggestions, or questions on this document should be addressed to Defense Supply Center-
Columbus, ATTN: DSCC-VAI, P.O. Box 3990, Columbus, OH 43218-3990, or emailed to
WireCable@dscc.dla.mil. Since contact information can change, please verify the currency of this
address information using the ASSIST Online database at http://assist.daps.dla.mil.
Downloaded from http://www.everyspec.com
资源描述:

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
关闭