INCH POUND
MIL-P-387C
INT.
AMENDMENT 2 (AR)
6 JUIV 1994
SUPERSEDING
INT. ANENDMENT 1 (AR)
26 March 1990
MILITARY SPECIFICATION
PENTAERYTHRITE TETRANITRATE
(Pm)
This Interim Amendment is approved for use within the U.S.
Army Armament, Munitions and Chemical Command, with
MIL-P-387C dated 8 December 1976.
PAGE 1
1.2 Classification: Delete “Class 1“ and substitute “Class 1
to 4“.
PAGE 8
*
Para 4.5.3 Melting Point. Add ‘or using Differential Scanning
Calorimetry (DSC) thermal analysis Method.
The peak maximum
of the endotherm shall be reported as the melting point.” to
the end of the paragraph.
*
Para 4.5.4 Nitrogen COntent.
Add ‘or using the Elemental
Analyzer Method.” to the end of the paragraph.
PAGE 10
*
Para 4.5.8 Delete
“4.5.8 Granulation.” and substitute “4.5.8.1
wet Sieves”
*
Add new para “4.5.8 Granulation Method.”
*
Add new para:
‘4.5.8.2 Sonic Sifter Method - Weigh approximate&’
2-10 pm of the dry sample and re-d~ at 70-80 degree C until
constant weight is obtained.
Preweigh each sieve and the
receiving pan. Stack the sieve in size order (coarsest on
top) .
Transfer sample to the top of the coarsest sieve.
Place sieve assembly in the Sonic Sifter. Set the SIFT/PULSE
MODE dial to a proper amplitude. proper amplitude is
Af4SC N/h
10f2
FSC 1376
~
ADprovecl
for publicrelease;dietribution is uni5.mlte#
Downloaded from http://www.everyspec.com