MIL-V-24630(SH)
AMENDMENT 3
29
June 1990
SUPERSEDING
AMENDMENT 2
18 April 1988
MILITARY SPECIFICATION
VA.LVES, CHECK, IN-LINE, FOR HYDRAULIC FLUID
AND LUBRICATING OIL FLUID
This amendment forms a part of MIL-V-24630(SH), dated 19 March 1984,
and is approved for use by the Naval Sea Systems Command, Department
of the Navy, and is available for use by all Departments and Agencies
of the Department of Defense.
PAGE 1
At bottom of page add:
“AMSC N/A
DISTRIBUTION STATEMENT A Approved for public release; distribution unlimited”
PAGE
8
3.5.9,
line 2:
Delete
“
4000
”
and substitute “3000”.
3.5.10, add: “The valve shall be subjected to a salt spray test if materials
other than specified herein are used for the valve external body.
When more than
one design is developed by the same contractor who uses the same method of surface
preservation for all designs,
only one representative unit shall require this
test, provided the same materials are used. Test data on similar equipment with
the same base and coating materials and equivalent coating thickness may be used
to meet this requirement.”
3.5.13: Delete.
*
3.5.14 and Table
3.9: Delete and
“3.9 Drawin~s.
II: Delete.
PAGE 10
substitute:
When specified (see 6.2.1),
reproducible (or microfilm)
assembly drawings-identical to those specified in
4
.
3
.
2
shall be provided
(see 6.2.2).”
PAGE 11
4.3, second sentence: Delete.
AMSC N/A
FSC 4820
DISTRIBUTION STATEMENT A Approved for public release; distribution unlimited
lof4