DATA ITEM DESCRIPTION
Title: HEMP TEST REPORT FOR MISSION CRITICAL SYSTEM IMMUNITY TEST
Number: DI-EMCS-82016 Approval Date: 20160404
AMSC Number: 9610 Limitation: N/A
DTIC Applicable: Yes GIDEP Applicable: N/A
http://www.dtic.mil/dtic/submit/
Office of Primary Responsibility: DTRA-DS
Applicable Forms: None
Use/Relationship: The HEMP Protection Subsystem’s Mission Critical System (MCS)
Immunity Test Report (MITR) describes the tests, analyses and inspections used by the
contractor and documents the results verifying compliance with MIL-STD-461 RS 105 and
CS116 testing (or equivalent), testing of each MCS to be installed in the ship during the
engineering development phase. The MITR provides the means for the government to evaluate
HEMP protection performance results.
a. This DID contains the format and content preparation instructions described in
Appendix B of MIL-STD-4023.
b. This DID is related to DI-EMCS-82015.
Requirements:
1. Reference documents. The applicable issue of the documents cited herein, including their
approval dates and any applicable amendments, notices, or revisions shall be as cited in the
solicitation or contract. MITR classification shall be determined using DTRA Security
Classification Guide for DoD Electromagnetic Pulse (EMP) Programs and Activities (U)
available by mail request to ATTN: J9/NT-NTSA/Rooney M., Defense Threat Reduction
Agency, 8725 John J. Kingman Road, MSC 6201 Fort Belvoir, Virginia 22060-6201, and any
relevant system specific classification guides.
2. Format. The MITR shall be in contractor format.
3. Content. The MITR shall describe the overall test results for the MCS immunity tests for
each requirement specified in the contract for the ship being developed.
3.1 Summary information. This report shall summarize the following:
3.1.1 Introduction.
a. MCS description including any pertinent test issues.
b. Statement of any assumptions and limitations associated with MCS immunity tests.