USACE / NAVFAC / AFCEC / NASA UFGS-31 31 16.19 (August 2022)
------------------------------------
Preparing Activity: NAVFAC Superseding
UFGS-31 31 16.1
9 (February 2016)
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated October 2022
**************************************************************************
SECTION TABLE OF CONTENTS
DIVISION 31 - EARTHWORK
SECTION 31 31 16.19
TERMITE CONTROL BARRIERS
08/22
PART 1 GENERAL
1.1 REFERENCES
1.2 ADMINISTRATIVE REQUIREMENTS
1.2.1 Pre-Installation Meetings
1.3 SUBMITTALS
1.4 QUALITY CONTROL
1.4.1 Qualifications
1.4.1.1 Steel Mesh Barrier System
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 SITE CONDITIONS
1.6.1 Environmental Requirements
1.7 WARRANTY
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.1.1 Steel Mesh System Description
2.1.2 Basaltic Sand System Description
2.2 MATERIALS
2.2.1 Asbestos Prohibition
2.2.2 Steel Mesh Materials
2.2.2.1 Steel Mesh Material Submittals
2.2.3 Accessories
2.2.4 Basaltic Sand
PART 3 EXECUTION
3.1 EXAMINATION
3.2 PREPARATION
3.2.1 Surface Preparation
3.3 INSTALLATION
3.3.1 Steel Mesh Instructions
3.3.1.1 Installation Sequence
SECTION 31 31 16.19 Page 1