REPORT DOCUMENTATION PAGE
OMB No. 0704-0188
The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources,
gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection
of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for information on Operations and Reports (0704-
0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to
any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.
PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS.
1. REPORT DATE (DD-MM-YYYY)
23-07-2012
3. DATES COVERED (From - To)
Test Operations Procedure (TOP) 10-2-204, General Tests of Personal
Protective Equipment (Non-ballistic) - Soft Armor
5c. PROGRAM ELEMENT NUMBER
7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES)
Commander
U.S. Army Aberdeen Test Center
TEDT-AT-WFS
Aberdeen Proving Ground, MD 21005-5059
8. PERFORMING ORGANIZATION
REPORT NUMBER
TOP 10-2-204
9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES)
Range Infrastructure Division (CSTE-TM)
US Army Test and Evaluation Command
2202 Aberdeen Boulevard
Aberdeen Proving Ground, MD 21005-5001
ACRONYM(S)
11. SPONSOR/MONITOR’S REPORT
NUMBER(S)
Same as item 8
12. DISTRIBUTION/AVAILABILITY STATEMENT
Distribution Statement A. Approved for public release; distribution is unlimited.
13. SUPPLEMENTARY NOTES
Defense Technical Information Center (DTIC), AD No.: ADA566201
This Test Operations Procedure (TOP) describes general procedures for conducting nonballistic testing of soft armor
systems. Tests include Bulk Materials, Visual Inspection, Bartacks, Component and Assembly, Construction Design,
Emergency Release Mechanism, Functional Integration, Hardware, Label Verification: Verbiage, Label Verification:
Dimensions and Font, Open Seam, Stitch Count, Stitch and Seam Type, Raw Edges, Stitch Tension, Thread Ends,
Weight, Materials Inspection Testing, Ballistic Filler Weight, Ballistic Panel Subcomponent Fit and Area, Bartack
Holding Strength, Dimensions: Bartack Length, Distance between Bartacks, Distance between Horizontal Webbing,
Buttonhole Cut, Length and Width, Drag Strap Extension Test Using Instron Machine, Emergency Release Anchor
Webbings, Pattern Matching, Pattern Matching: Ballistic Filler, Ply Count, Thickness: Ballistic Filler, and Vertical
Soft Body Armor Personal Protective Equipment Non-ballistic
16. SECURITY CLASSIFICATION OF:
ABSTRACT
SAR
OF
PAGES
59
19a. NAME OF RESPONSIBLE PERSON
19b. TELEPHONE NUMBER (include area code)
Standard Form 298 (Rev. 8-98)
Prescribed by ANSI Std. Z39-18
Downloaded from http://www.everyspec.com