PROCEDURE TM-11-6210-299-13&P
1) Install Batteries, Tripods, Antennas ........................................... 0005-1
2) Test RCM, MSM, and LMs ............................................................ 0005-2
3) Configure MSM using Setup Configuration Menu
a. Change Sensor and Group IDs ............................................... 0008-1
b. Change VHF Channel .............................................................. 0008-5
4) Attach LMs ..................................................................................... 0008-8
5) Configure RCM using RCM Setup Menu
a. Change MSM Sensor and Group IDs ..................................... 0010-1
b. Change VHF Channel .............................................................. 0010-4
c. Change MSM Alarm Mode ....................................................... 0010-6
d. Enable Tamper Alarm .............................................................. 0010-10
6) Position the MSM and LMs
a. Conduct Walk-Test................................................................... 0006-4
b. Arm System using RCM MSM Control Menu ........................ 0006-8
7) Set MSM Alarm Responses using MSM
a. Change the MSM Alarm Mode (Light – Constant/Strobe/Visual)
.................................................................................................... 0009-1
b. Change the MSM Audio Duration (Audio – On/Off) ............... 0009-6
8) Arm the System from the RCM.................................................... 0006-8
BASIC EMPLACEMENT PROCEDURES
GTA 19-01-005 Jan 2010
LIGHTING KIT, MOTION DETECTOR (LKMD) AN/GAR -2
BATTERY LIFE EXPECTANCY
Battery Type Temperature Device Mission Life
Days Hours
Lithium
Ambient
(+21°C, +70°F)
RCM ................. 21 ................. 525
MSM ................... 8 ................. 200
LM .................... 10 ................. 250
Hot
(+49°C, +120°F)
RCM ................. 19 ................. 473
MSM ................... 7 ................. 180
LM ...................... 9 ................. 225
Cold
(-32°C, -25°F)
RCM ................. 16 ................. 394
MSM ................... 6 ................. 150
LM ...................... 7 ................. 188
Alkaline
Ambient
(+21°C, +70°F)
RCM ................. 18 ................. 450
MSM ................... 7 ................. 175
LM ...................... 5 ................. 120
Hot
(+49°C, +120°F)
RCM ................. 16 ................. 405
MSM ................... 6 ................. 158
LM ...................... 4 ................. 108
Cold
(-20°C, -4°F)
RCM ................. 10 ................. 243
MSM ................... 3 ................... 95
LM ...................... 2 ................... 65
Recharge-
able
Ambient
(+21°C, +70°F)
RCM ................. 13 ................. 325
MSM ................... 5 ................. 120
LM ...................... 6 ................. 150
Hot
(+49°C, +120°F)
RCM ................. 11 ................. 276
MSM ................... 4 ................. 102
LM ...................... 5 ................. 128
Cold
(-20°C, -4°F)
RCM ................... 2 ................... 65
MSM ................... 1 ................... 24
LM ...................... 1 ................... 30
PMCS
BEFORE OPERATIONS STATUS
1) Batteries (Install new batteries) ................................................... GO/NO GO
2) LCD Screens (Check for damage) ............................................... GO/NO GO
3) PIR/Microwave Sensors (Check for damage) ............................ GO/NO GO
4) Antennas (Check for damage) ..................................................... GO/NO GO
5) Seals (Check for damage) ............................................................ GO/NO GO
6) Tripods (Check for damage, missing knobs) ............................... GO/NO GO
7) External Power Cables (Check for damage) .............................. GO/NO GO
DURING OPERATIONS STATUS
1) Battery Power Levels (Install new batteries) .............................. GO/NO GO
2) Field of View (Aiming, coverage, obstructions) ........................... GO/NO GO
3) PIR/Microwave Sensors (Damage, obstructions) ...................... GO/NO GO
4) Dirt/Debris (Clean sensors, LCD screens) .................................. GO/NO GO
AFTER OPERATIONS STATUS
1) Batteries (Remove, clean compartment) ..................................... GO/NO GO
2) LCD Screens (Clean, check for damage) .................................... GO/NO GO
3) PIR/Microwave Sensors (Clean, check for damage) ................. GO/NO GO
4) Antennas (Check for damage) ..................................................... GO/NO GO
5) Seals (Check for damaged) .......................................................... GO/NO GO
6) Tripods (Check for damage, missing knobs) ............................... GO/NO GO
7) External Power Cables (Check for damage) .............................. GO/NO GO
WARNING SUMMARY
CHEMICAL—Battery chemicals can cause burns to unprotected skin.
EAR PROTECTION—Failure to wear ear protection can cause
hearing damage or loss.
LED LIGHT— Direct exposure can cause temporary blindness and
permanent damage.
EXPLOSIVE— Do not Incinerate batteries; dispose of properly.
LKMD EMPLACEMENT DATA
1) MSM Optimal Intrusion Detection Area
2) MSM Position (Grid location)
3) MSM Group ID or Individual MSM ID
4) Azimuth to MSM (from RCM location)
5) Distance to MSM (from RCM location)